Product testing & R&D

See Exactly What Your Product Leaves Behind

Glo Germ shows where a vacuum, wipe, mop, spray or self-cleaning cycle leaves material behind. Twelve free test protocols turn UV images into repeatable, scored results your engineers can act on.

Engineer inspecting fluorescent powder left by a vacuum cleaner under UV light

Where it is used

Built for Your Test Lab

Used by engineering and product teams at leading appliance, floor-care and semiconductor companies. Use Glo Germ wherever you need to see particle pick-up, residue removal or contamination transfer.

Handling and Glove Transfer

Electronics · Precision engineering

Handling and Glove Transfer

Map how material moves from gloves and tools onto boards, components and workstations, and show operators exactly where contamination comes from.

See touch-point mapping
Wipes, Mops, Sprays and Cleaning Heads

Cleaning products · Surface technology

Wipes, Mops, Sprays and Cleaning Heads

Compare products and techniques on identical test tiles, and photograph precisely which areas each one misses or smears.

See wipe and mop coverage
Wash Programmes and Textile Transfer

Laundry · Textiles

Wash Programmes and Textile Transfer

Visualise transfer from soiled to clean textiles and residue left after a wash programme, subject to fabric compatibility checks.

Talk to us about laundry testing

Free test protocols

Test Protocols with Record Sheets

Each protocol includes the question it answers, equipment, a step-by-step method, scoring guidance and a printable record sheet. Download a single protocol or the complete pack.

Start here · Method foundations

Method Foundations · 4 protocols

Plan a fair test, capture consistent UV images, score them, and keep demonstrations and marketing claims backed by evidence.

Show the 4 protocols

Application protocols

Application Protocols · 8 tests

Floor pick-up, edges, emissions, wipes and mops, re-deposition, airborne dispersal, touch points and self-cleaning.

Show the 8 protocols

How a test runs

Plan, Apply, Run, Score

Every protocol follows the same structure, so results are repeatable and comparable between runs, products and test sites.

01

Plan

Write one question, fix the variables and include a control run.

02

Apply

Weigh a set amount of tracer onto a marked test area or product.

03

Run

Operate the product the same way every time, with at least three runs per condition.

04

Image & score

Photograph under UV with a reference card, then grid-score or measure glowing area.

Standards & policy

Why Visual Evidence Matters Now

Performance claims for cleaning products and appliances face closer scrutiny than ever. Standard methods give the headline numbers; Glo Germ shows your engineers where material is left and why.

IEC 62885-2:2026

IEC · Edition 3 published July 2026

The dry vacuum cleaner performance standard now covers cordless as well as mains-operated machines, replacing the 2021 edition. Use it for published figures; use Glo Germ to see where and why.

IEC webstore

IEC/ASTM 62885-7 and IEC 63086-1

IEC · Robots and air cleaners

The matching performance methods for cleaning robots and household air cleaners. Protocols 04, 05 and 09 add visual evidence of coverage and settling patterns.

CAP Code rule 3.7

ASA / CAP · UK advertising code

Marketers must hold documentary evidence for objective claims before publication. Protocol 12 builds a claim record behind every demonstration and video.

ASA guidance

Digital Markets, Competition and Consumers Act 2024

CMA · Direct enforcement since 6 April 2025

The CMA can now decide consumer law breaches itself and fine businesses up to 10% of global turnover, raising the stakes for unsupported performance claims.

GOV.UK

Ecodesign review: vacuum cleaners

European Commission · Review under way

Draft revisions propose bringing battery-operated and robot cleaners into scope. They currently sit outside Regulation (EU) 666/2013, so more products may face performance limits.

European Commission

ISO/IEC 17025:2017

ISO / IEC · Testing laboratory competence

The international standard for testing laboratories. The protocols follow the same disciplines: documented methods, controls, replicates and traceable records.

ISO

Glo Germ is a visual tracer. These are in-house development methods, not standardised test methods, and are not produced or endorsed by IEC, BSI, the ASA or the CMA. Use recognised standards for published performance figures.

Recommended equipment

Kits for Your Test Lab

Everything the protocols use: Powder for dry particles, Surface Detection Gel for wipe and mop tests, MIST for airborne dispersal, and Gel for touch-point mapping.

Glo Germ Powder Kit – 6 Bottles, UV Torch & Case

Glo Germ Powder Kit – 6 Bottles, UV Torch & Case

Six bottles of fluorescent powder with a UV torch, for floor, edge, emission and maintenance tests.

£255.00 ex VAT

View Product
Glo Germ Surface Cleaning Detection Gel – 50 ml

Glo Germ Surface Cleaning Detection Gel – 50 ml

Dot onto test tiles for wipe, mop and spray-and-wipe coverage tests.

£14.25 ex VAT

View Product
Glo Germ MIST Kit – Basic

Glo Germ MIST Kit – Basic

Releases fluorescent droplets for airborne dispersal and air cleaner tests.

£95.48 ex VAT

View Product
Glo Germ Kit 1006 – Gel

Glo Germ Kit 1006 – Gel

Gel and UV light for touch-point mapping with volunteers.

£105.00 ex VAT

View Product

Common questions

FAQs for R&D and Test Teams

What is the difference between Gel, Oil, Powder, Surface Detection Gel and MIST?

Gel is the standard choice for handwashing demonstrations and washes off easily. Oil stays on skin a little longer and suits longer exercises. Powder shows dry particle transfer and cross-contamination. Surface Cleaning Detection Gel marks surfaces for cleaning checks. MIST is a spray that shows how droplets from a cough or sneeze land on nearby surfaces.

R&D teams: Protocol 01 in our Product Testing pack has a tracer selection table.

Can Glo Germ results be used for published product performance figures?

No. Use the recognised standards, such as IEC 62885-2, for published pick-up, emission or air cleaning figures. Glo Germ is for development work: seeing where material is left and why, comparing design options and building demonstrations.

Is Glo Germ Powder a calibrated test dust?

No. It is a fluorescent demonstration material, not a certified test dust or calibrated test particle. Results depend on how it is applied, the surface, airflow and inspection conditions.

Can we use Glo Germ in launch videos and trade show demonstrations?

Yes, and it is very effective on camera. Protocol 12 in our Product Testing pack sets up a claim record so you hold the test evidence before anything is published, as the CAP Code requires.

How do we turn UV images into numbers?

Protocol 03 in our Product Testing pack gives two methods: a quick grid score by eye, and percentage glowing area using the free Fiji (ImageJ) software. Use the same method for every run in a study.

Is Glo Germ suitable for electronics, precision manufacturing and textile research?

Yes, for contamination-transfer demonstrations and development work, after a compatibility test on your materials or fabrics. It is not a substitute for cleanroom particle monitoring, and textile results show visible residue only, not microbial decontamination.

Do you accept purchase orders?

Yes. We accept purchase orders from NHS trusts, councils, schools, universities, care groups and businesses. Send your PO or new supplier form through our contact form, call 0333 054 1633 or email info@chem-x.uk.

We can usually set up a trade account the same day.

Do you deliver outside the UK?

Yes. We supply customers across the EU and further afield. Send us the products, quantities and delivery address, and we will quote carriage, customs and taxes for your destination.

Business purchasing

Equip Your Test Lab

Order online, or contact ChemX with your purchase order, a new supplier form or a request for a quotation for bulk or repeat supply.